The 100BASE-ZX PTMs can be used on the LNW74, LNW87, and LNW170.
The following are the 100BASE-ZX system specifications:
The table below describes some of the transmit specifications for 100BASE-ZX.
Description |
100BASE-ZX |
---|---|
Transmitter type |
Longwave Laser |
Signaling speed (range) |
125 MBd (± 50 ppm) |
Wavelength (range) |
1480 to 1600 nm |
Maximum RMS Spectral Width (σ) |
1 nm |
Average launch power (max) |
2.0 dBm |
Average launch power (min) |
−3.0 dBm |
The table below describes some of the receiver specifications for 100BASE-ZX.
Description |
100BASE-ZX |
---|---|
Signaling speed (range) |
125 MBd (±50 ppm) |
Wavelength (range) |
1480 to 1600 nm |
Average receive power (max) |
−8.0 dBm |
Receive sensitivity |
−31.0 dBm |
Return loss (min) |
25.0 dB |
The worst-case power budget and link penalties for a 100BASE-ZX channel are shown in the table below.
Parameter |
100BASE-ZX |
---|---|
Maximum Channel Insertion Loss |
27.0 dB |
Minimum Channel Insertion Loss |
10.0 dB |
Maximum Dispersion |
1700 ps/nm |
Optical Path Penalty |
1 dB |
Performance monitoring capabilities are available on the 100BASE-ZX interface. A detailed list of monitored parameters can be found in Performance monitoring.
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |