The 100BASE-ZX PTMs can be used on the LNW74, LNW87, and LNW170.
The following are the 100BASE-ZX system specifications:
The table below describes some of the transmit specifications for 100BASE-ZX.
|
Description |
100BASE-ZX |
|---|---|
|
Transmitter type |
Longwave Laser |
|
Signaling speed (range) |
125 MBd (± 50 ppm) |
|
Wavelength (range) |
1480 to 1600 nm |
|
Maximum RMS Spectral Width (σ) |
1 nm |
|
Average launch power (max) |
2.0 dBm |
|
Average launch power (min) |
−3.0 dBm |
The table below describes some of the receiver specifications for 100BASE-ZX.
|
Description |
100BASE-ZX |
|---|---|
|
Signaling speed (range) |
125 MBd (±50 ppm) |
|
Wavelength (range) |
1480 to 1600 nm |
|
Average receive power (max) |
−8.0 dBm |
|
Receive sensitivity |
−31.0 dBm |
|
Return loss (min) |
25.0 dB |
The worst-case power budget and link penalties for a 100BASE-ZX channel are shown in the table below.
|
Parameter |
100BASE-ZX |
|---|---|
|
Maximum Channel Insertion Loss |
27.0 dB |
|
Minimum Channel Insertion Loss |
10.0 dB |
|
Maximum Dispersion |
1700 ps/nm |
|
Optical Path Penalty |
1 dB |
Performance monitoring capabilities are available on the 100BASE-ZX interface. A detailed list of monitored parameters can be found in Performance monitoring.