The LNW2 SYSCTL circuit pack faceplate contains the following push-button switches and LEDs:
The alphanumeric LED numeric display is used to identify the remote system presently displayed on the local user panel.
A green PWR ON LED is lighted when the shelf is receiving −48 V power. A green ACO LED is lighted when the ACO function is active.
The SEL, ACO SW, and UPD INIT push-buttons are provided to control system operation.
A red LED FAULT indicator is provided on all circuit packs. A green LED ACTIVE indicator is provided on all 1x1 protected circuit packs to indicate which circuit packs are actively carrying traffic.
The office alarms interface is a set of discrete relays that control office audible and visual alarms. Separate relays handle CR, MJ, and MN alarms. Each contact closure is rated at 1 A, 60 V maximum. The CR and MJ alarms can be wire-ORed. The CR alarm relays are fail safe against unprotected power failures.