A remote client signal or VCG failure has been detected and the specified Data or Ethernet port has automatically shut down.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Not Alarmed (NA) |
ASAP Type |
Data Port Fast Ethernet Port Gigabit Ethernet Port |
AID Type |
Data port Ethernet port |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
ALS (Auto Link Shutdown) |
Effect on Service |
SA |
Alarm Entity Type |
DATA FELAN GELAN |
Description |
AUTO link shutdown |
Likely Cause |
Either a remote client signal failure or a VCG failure has been detected and the port Remote Client Fail Link Shutdown parameter is enabled. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively). |
Action |
Proceed to Procedure 5-5: Clear "AUTO link shutdown" alarm. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |