inc. OCN section trace identifier mismatch, diagnostic

Description

The network element detected a mismatch between the actual received Section Trace format/message and the provisioned expected Section Trace format/message. (The Receive Section Trace Identifier Monitor and Receive Section Trace Identifier Mismatch Consequent Action parameters are Enabled.)

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Minor (MN)

ASAP Type

OCN Port

AID Type

OC-N Line

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

TIM-S-D (Trace Identifier Mismatch, Section - Diagnostic)

Effect on Service

NSA

Alarm Entity Type

OCN

Description

inc. OCN section trace identifier mismatch, diagnostic

Likely Cause

The actual received Section Trace Format and/or Section Trace Value do not match the provisioned Expected Receive Section Trace Format and/or Expected Receive Section Trace Value parameters.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the affected circuit pack.

Action

Proceed to Procedure 5-73: Clear "inc. section trace identifier mismatch" alarms.