The network element detected a mismatch between the actual received Section Trace format/message and the provisioned expected Section Trace format/message. (The Receive Section Trace Identifier Monitor and Receive Section Trace Identifier Mismatch Consequent Action parameters are Enabled.)
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Minor (MN) |
|
ASAP Type |
OCN Port |
|
AID Type |
OC-N Line |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
TIM-S-D (Trace Identifier Mismatch, Section - Diagnostic) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
OCN |
|
Description |
inc. OCN section trace identifier mismatch, diagnostic |
|
Likely Cause |
The actual received Section Trace Format and/or Section Trace Value do not match the provisioned Expected Receive Section Trace Format and/or Expected Receive Section Trace Value parameters. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the affected circuit pack. |
|
Action |
Proceed to Procedure 5-73: Clear "inc. section trace identifier mismatch" alarms. |