inc. LAG PLCF

Description

The Link Aggregation Group is using the standard LACP protocol and one or more members of the Link Aggregation Group is not receiving standard compliant messages.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Alarmed (NA)

ASAP Type

Link Aggregation Group

AID Type

LAG

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

PLCF (Partner LAG Configuration Failed)

Effect on Service

SA

Alarm Entity Type

LAG

Description

inc. LAG PLCF

Likely Cause

A configuration conflict with the interfacing customer Link Aggregation Group (LAG partner). The interfacing customer equipment may not be configured for Link Aggregation or has Link Aggregation Control Protocol (LACP) disabled.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack.

Action

Proceed to Procedure 5-64: Clear "inc. LAG" alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.