The system cannot determine which generic or database to use and has entered the Maintenance mode.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Not Alarmed (NA) |
|
AID Type |
Blank |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
DATAFLT (Data Integrity Fault) |
|
Effect on Service |
Standing Condition (SC) |
|
Alarm Entity Type |
COM |
|
Description |
Maintenance Mode |
|
Likely Cause |
The generic is not valid, the database is not valid, or there are multiple valid generics and/or databases. At least one other alarm/standing condition is also reported indicating why maintenance mode was entered. |
|
Visible Indication |
Lighted ABN LED on the SYSCTL faceplate. The IND display scrolls MPx.x where x.x is the generic number. |
|
Action |
Proceed to Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions. |