VCG Failure of LCAS Protocol (Sink)

Description

This alarm indicates an LCAS-enabled VCG receive protocol failure.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

SA Default: Minor (MN)

NSA Default: Minor (MN)

ASAP Type

VCG Port

AID Type

VCG

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

VCGFOPR (Failure of Protection, Sink)

Effect on Service

SA or NSA

Alarm Entity Type

VCG

Description

VCG Failure of LCAS Protocol (Sink)

Likely Cause

A combination of link failures and provisioning actions are interfering with each other, or a misalignment exists between the source and sink end of the Sequence Numbers and Member Status information.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-146: Clear "VCG Failure of LCAS Protocol" alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.