This alarm indicates an LCAS-enabled VCG transmit protocol failure.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) SA Default: Minor (MN) NSA Default: Minor (MN) |
ASAP Type |
VCG Port |
AID Type |
VCG |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
VCGFOPT (Failure of Protection, Source) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
VCG |
Description |
VCG Failure of LCAS Protocol (Source) |
Likely Cause |
A combination of link failures and provisioning actions that interfered with each other, or a misalignment between the source and sink end of the Sequence Numbers and Member Status information. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-146: Clear "VCG Failure of LCAS Protocol" alarms. |