Procedure 5-85: Clear "Inconsistent Ring Prot Mode" alarm

- Overview

This procedure is used to clear an Inconsistent Ring Prot Mode alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipmentin this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear an Inconsistent Ring Prot Mode condition.

 
1

From the WaveStar® CIT System View, click theAlarm List button and locate the Inconsistent Ring Prot Mode alarm in the resulting Alarm List and note the corresponding AID.


2

At each node in the BLSR, select View → Equipment to access the ports that interface with the BLSR and verify that the port Application parameter is provisioned 2F BLSR.

If required, select Configuration → Equipment to access the ports that interface with the BLSR and provision the port Application parameter 2F BLSR.


3

From the System View, click the Alarm List button and click Refresh.

Important!

While the Automatic Ring Discovery (ARD) feature updates the ring map, there will be momentary alarms, such as Ring Prot Switching Suspended, Ring Discovery In Progress. These alarms will clear automatically when automatic ring discovery completes.

Result:

The Inconsistent Ring Prot Mode alarm is no longer present.


End of steps