Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a Temporarily NUT Provisioned condition.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the Temporarily NUT Provisioned condition in the resulting alarm list and note the corresponding AID. |
2 |
From the System View, select Configuration → Equipment, click the Ptn Grp tab, highlight the 2F BLSR, and click Select. Result: The Configure Equipment window opens. |
3 |
In the Local NUT section of the Configure Equipment window, change NUT Protection Attribute to "Protected" or "Not Protected" from "Temporary not Protected", and then click Apply. |
4 |
In the Provision Parameters for Equipment window, click Close. |
5 |
From the System View, click the Alarm List button and click Refresh. Result: The Temporarily NUT Provisioned condition is no longer present. End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |