Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to identify and clear a Circuit Provisioning Error alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the Circuit Provisioning Error alarm in the resulting alarm list and note the corresponding AID. |
2 |
From the System View, select View → Rings → Circuit. Result: The View Circuit window opens. |
3 |
In the View Circuit window, locate the incorrectly provisioned source or destination (loca/locz) at some point in the circuit and record the TID of that node. Click Close on the View Circuit window. |
4 |
Log in to the NE with the incorrectly provisioned source or destination (loca/locz). |
5 |
From the System View, select Configuration → Cross-Connections to access the Cross-Connection Wizard and modify the existing cross-connection. End of steps |