Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a forced switch condition.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the forced switch condition in the resulting alarm list and note the corresponding AID. |
2 |
From the System View, select Fault → Protection Switch, highlight the affected Protection Group, and then click Select. Result: On the right side of the Switch Protection window, the Switch Type: pull-down menu appears. |
3 |
From the Switch Type: pull-down menu, select Reset and click Apply. Result: A warning message appears asking you to confirm executing this command. |
4 |
Click Yes to release the forced switch. Click Close to exit the Switch Protection window. End of steps |