Procedure 5-80: Clear "incoming CRC-4 MFA mismatch" condition

- Overview

This procedure is used to clear an incoming CRC-4 MFA mismatch condition.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear an incoming CRC-4 MFA mismatch condition.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the incoming CRC-4 MFA mismatch condition in the resulting Alarm List and note the corresponding AID.


2

To clear the incoming CRC-4 MFA mismatch condition, either change the signal format of the incoming E1 signal to CRC-4 or change the signal format parameter of the local E1 port to Frame Alignment Signal according to local procedures.

If changing the signal format of the...

Then...

incoming E1 signal,

notify personnel at the site supplying the E1 signal to change the signal format to CRC-4.

STOP! End of Procedure.

local E1 port,

go to the next step.


3

From the System View, select Configuration → Equipment. Expand the required circuit pack and TUG signals. Select the required E1 port and click Select.

Result:

The port provisionable parameters appear.


4

Provision the Signal Format parameter of the E1 port to Frame Alignment Signal and click Apply.

Result:

A warning message appears asking you to confirm executing this command. Click Yes and Close.


End of steps