1 |
From the WaveStar® CIT System View, click Alarm List button and locate the Inconsistent VT BLSR Access condition the resulting Alarm List and note the corresponding AID.
|
2 |
To clear the Inconsistent VT BLSR Access condition, either delete the offending cross-connection or provision the Inconsistent VT BLSR Access Alarm Level to Not Reported according to local procedures.
If... |
Then... |
deleting the offending cross-connection, |
Perform the following.
-
From the System View, select View → Cross-Connections, then click the Ptn Grp tab. Select the required 2F BLSR protection group and click Select. The View Cross-Connection window opens.
-
Identify the VT1.5 add/drop and/or the VT-accessed STS-1 pass through cross-connections. Record the Source, Destination, and Rate, then click Close.
-
From the System View, select Configuration → Cross-Connections to access the Cross-Connection Wizard and delete the required cross-connection. |
provisioning the Inconsistent VT BLSR Access Alarm Level parameter to Not Reported, |
Perform the following.
-
From the System View, select Configuration → Equipment, then click the Ptn Grp tab. Select the required 2F BLSR protection group and click Select. The protection group parameters appear.
-
Provision the Inconsistent VT BLSR Access Alarm Level to Not Reported. Click Apply and Close. |
|
3 |
From the System View, click the Alarm List button and click Refresh.
|
4 |
Is the Inconsistent VT BLSR Access condition still present?
If... |
Then... |
Yes |
Continue with the next step. |
No |
STOP! End of Procedure. |
|
5 |
From the System View, select Fault → Reset → System Controller.
Result:
The Reset System Controller window opens.
|
6 |
Important!
Do NOT select Restore the system-level parameters to their default values (Phase 9) on an in-service system. Phase 9 resets all provisionable parameters to the default values and the system controller executes a full power-up sequence.
Click Reset the system software without changing parameters (Phase 3). Click OK.
Result:
A warning appears asking you to confirm executing this command.
|
7 |
Click Yes to execute the command.
Result:
The system resets and you are logged off the system.
A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing.
|
8 |
Log back into the network element. Click the Alarm List button and click Refresh.
|
9 |
From the System View, click the Alarm List button and click Refresh.
If the Inconsistent VT BLSR Access condition is still present, contact your next level of support.
End of steps |