Procedure 5-87: Clear "inhibit switch" condition

- Overview

This procedure is used to clear an inhibit switch condition.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear an inhibit switch condition.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the inhibit switch condition in the resulting Alarm List and note the corresponding AID and the Alarm Entity Type.


2

If ...

Then...

External Synchronization References

Use Fault → Timing/Sync Protection Switch → System Timing Reference/Source Switch to perform a Reset Switch Command.

Equipment Protection Group

Use Fault → Protection Switch to access the required 1+1 equipment protection group and perform a Reset Switch Type.


End of steps