Complete the following steps to clear an Invalid Subshelf Configuration alarm.
1 |
Important! When the shelf is in the Maintenance Mode state, the IND display on the SYSCTL circuit pack faceplate shows MPx.x (where x.x is the generic number). If the shelf is in the Maintenance Mode state, the default User IDs/passwords must be used to log in to the shelf. LUC01, LUC02, and LUC03 are the default privileged User IDs, and DMX2.5G10G is the default privileged password. Log in to the shelf using the WaveStar® CIT Graphical Mode. Result: The Maintenance Mode Wizard (Screen 1 of 6) appears. Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session |
2 |
Perform the following to choose the required subshelf configuration file (ssconfig.dat) on both NVMs.
Result: The shelf resets and you are logged off the system. A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing. |
3 |
Important! The provisioned User IDs/passwords must be used to log in to the shelf. When the reset is complete, log back into the shelf. Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session End of steps |