Procedure 5-135.2: Clear "Multiple Main Shelf TIDs" alarm

Steps

Complete the following steps to clear an Multiple Main Shelf TIDs alarm.

 
1

Using local procedures and office records, determine which shelf connected to the LAN3 control communications link has the duplicate TID.

At the shelf with the duplicate TID, select Administration → Set TID to reprovision the duplicate TID.


2

Important!

When the shelf is in the Maintenance Mode state, the IND display on the SYSCTL circuit pack faceplate shows MPx.x (where x.x is the generic number).

If the shelf is in the Maintenance Mode state, the default User IDs/passwords must be used to log in to the shelf. LUC01, LUC02, and LUC03 are the default privileged User IDs, and DMX2.5G10G is the default privileged password.

Log in to the shelf using the WaveStar® CIT Graphical Mode.

Result:

The Maintenance Mode Wizard (Screen 1 of 6) appears.

Reference:

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


3

Perform the following to verify the generic, database, and subshelf configuration file (ssconfig.dat) on both NVMs, and reset the shelf.

  1. Follow the Maintenance Mode Wizard (Screen 1 of 6) instructions to set the date and time and click Next.

  2. Follow the Maintenance Mode Wizard (Screen 2 of 6) instructions to choose/download a generic and click Next.

  3. Follow the Maintenance Mode Wizard (Screen 3 of 6) instructions to choose/download a database and click Next.

  4. Follow the Maintenance Mode Wizard (Screen 4 of 6) instructions to use the selected generic and database and click Next.

  5. Follow the Maintenance Mode Wizard (Screen 5 of 6) instructions to choose a subshelf configuration. and click Next.

  6. Follow the Maintenance Mode Wizard (Screen 6 of 6) instructions and verify that the correct generic, database, and subshelf configuration were selected. Then click Finish.

Result:

The shelf resets and you are logged off the system.

A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing.


4

Important!

The provisioned User IDs/passwords must be used to log in to the network element.

When the reset is complete, log back into the shelf.

Reference:

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


End of steps

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.