Procedure 5-70: Clear "inc. ODU2 LCK/OCI" alarms

- Overview

This procedure is used to clear the following inc. ODU2/OTU2 alarms:

  • inc. ODU2 LCK

  • inc. ODU2 OCI

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear an inc. ODU2 LCK/OCI alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the inc. ODU2 LCK/OCI alarm in the resulting alarm list and note the corresponding AID.


2

Important!

The condition (trouble) is not in the local network element. There is a locked/open optical connection at an upstream network element.

Follow local procedures to isolate and clear the network trouble between the far-end network element and the local network element.


End of steps