Procedure 5-112: Clear "Path Integrity Failure" alarm

- Overview

This procedure is used to clear a Path Integrity Failure alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to identify and clear a Path Integrity Failure alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the Path Integrity Failure alarm in the resulting alarm list and note the corresponding AID.


2

From the System View, select View → Rings → Circuit.

Result:

The View Circuit window opens.


3

In the View Circuit window, locate the PIF (path integrity failure) at some point in the circuit and record the TID of that node. Click Close on the View Circuit window.


4

Log in to a remote NE with the missing or incorrect cross-connection.


5

From the System View, select Configuration → Cross-Connections to access the Cross-Connection Wizard and provision a new (missing) cross-connection in the circuit or to modify the existing cross-connection.


End of steps