Automatic protection switch primary section mismatch

Description

There is a mismatch detected in the primary section of the APS channel, specifically K2 byte, bits 1–4. Therefore, the near-end and far-end network elements of a 1+1_OPTM protection switching span do not agree on the primary section. The APS channel is provided by the K1 and the K2 bytes in the SONET section overhead of an STS-N to communicate the protection switching protocol between the local and far-end nodes.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Major (MJ)

ASAP Type

1+1 Optimized Protection Group

AID Type

OC-N line (1+1 optimized protection group)

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

APSPSM (APS Primary Section Mismatch)

Effect on Service

NSA

Alarm Entity Type

OCN

Description

Automatic protection primary section mismatch

Likely Cause

User selected Fault → Protection Switch and highlighted 1+1_OPTM Line Protection Group, and provisioned the Switch Type as Lockout.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-8: Clear "Automatic protection switch primary section mismatch" alarm.