A lockout of switching on a 1+1 equipment-protected pair (DS3/EC1, TMUX, or high-speed Main), because the provisioned threshold for number of switches has been exceeded.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Not Alarmed (NA) |
|
AID Type |
Slot |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
WKSWPR-1 (Working facility/equipment switched to protection unit 1) WKSWPR-2 (Working facility/equipment switched to protection unit 2) |
|
Effect on Service |
Standing Condition (SC) |
|
Alarm Entity Type |
EQPT |
|
Description |
automatic lock |
|
Likely Cause |
System has locked protection switching between a 1+1 equipment-protected pair because the provisioned number of consecutive APS switches has occurred (DS3/EC1, TMUX, or high-speed Main). |
|
Visible Indication |
Lighted ABN LED on the SYSCTL faceplate. |
|
Action |
Proceed to Procedure 5-6: Clear "automatic lock" condition. |