The firmware in the indicated circuit pack does not match the active software generic running on the network element.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Not Alarmed (NA) |
|
AID Type |
Slot |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
FACTERM (Facility termination equipment failure) |
|
Effect on Service |
Standing Condition (SC) |
|
Alarm Entity Type |
COM |
|
Description |
CP software upgrade required |
|
Likely Cause |
Either a new version of the software generic was applied to the shelf and the indicated circuit pack did not update automatically, or a new circuit pack was inserted into the shelf and the active software generic on the shelf does not match the new circuit pack. |
|
Visible Indication |
Lighted ABN LED on the SYSCTL faceplate. |
|
Action |
Proceed to Procedure 5-17: Clear "CP software upgrade required" condition. |
| November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |