CP not allowed - crs

Description

The circuit pack does not support the cross-connection(s) currently provisioned for the slot.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

NSA Default: Minor (MN)

ASAP Type

Circuit pack

AID Type

Slot

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

NSA

Alarm Entity Type

EQPT

Description

CP not allowed - crs

Likely Cause

A circuit pack was inserted into a slot that was already provisioned with cross-connections, and those provisioned cross-connections are not supported by the new circuit pack.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the affected circuit pack.

Action

Proceed to Procedure 5-14: Clear "CP not allowed - crs" alarm.