An unsupported circuit pack type is inserted into a slot.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) NSA Default: Minor (MN) |
|
ASAP Type |
Circuit pack |
|
AID Type |
Slot |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
FACTERM (Facility termination equipment failure) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
EQPT |
|
Description |
CP not allowed - eqpt |
|
Likely Cause |
A circuit pack was inserted into a slot that was already provisioned for another circuit pack type, and the new circuit pack is not supported by that slot. For example, an electrical circuit pack was inserted into slot G1/G2, and the circuit pack was not recognized by the SYSCTL. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the affected circuit pack. |
|
Action |
Proceed to Procedure 5-15: Clear "CP not allowed - eqpt" alarm. |