CP not allowed - eqpt

Description

An unsupported circuit pack type is inserted into a slot.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

NSA Default: Minor (MN)

ASAP Type

Circuit pack

AID Type

Slot

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

NSA

Alarm Entity Type

EQPT

Description

CP not allowed - eqpt

Likely Cause

A circuit pack was inserted into a slot that was already provisioned for another circuit pack type, and the new circuit pack is not supported by that slot. For example, an electrical circuit pack was inserted into slot G1/G2, and the circuit pack was not recognized by the SYSCTL.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the affected circuit pack.

Action

Proceed to Procedure 5-15: Clear "CP not allowed - eqpt" alarm.