DATA CP failed

Description

Either an internal equipment failure of the specified Fibre Channel circuit pack was detected, or a communications problem between the Fibre Channel circuit pack and the System Controller (SYSCTL) circuit pack was detected.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Critical (CR)

ASAP Type

Circuit pack

AID Type

Slot

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

SA

Alarm Entity Type

EQPT

Description

DATA CP failed

Likely Cause

A Fibre Channel circuit pack carrying service failed.

A failure on a Fibre Channel circuit pack is always SA as the Fibre Channel circuit packs are unprotected.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the failed circuit pack.

Action

Proceed to Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.