inc. data type mismatch

Description

The alarm indicates that the Payload Type Identifier in the GFP header does not match the expected value client type (Ethernet or Fibre Channel [FC]). The alarm is valid on the LNW63, LNW66, LNW67, LNW68, and LNW73/73C circuit packs.

Alarm Data

Value/Meaning

Severity Levels

Not Alarmed (NA)

AID Type

VCG

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

MISC (Miscellaneous condition)

Effect on Service

Standing Condition (SC)

Alarm Entity Type

VCG

Description

inc. data type mismatch

Likely Cause

Inconsistent Equipage: One end of a circuit is equipped with an Ethernet pack and the other end is equipped with a Fiber Channel pack.

Incorrect cross-connect provisioning: An Ethernet pack is connected through the network to a Fiber Channel pack.

Inconsistent GFP FCS provisioning.

Visible Indication

None

Action

Proceed to Procedure 5-48: Clear "inc. data type mismatch" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.