The alarm indicates that the Payload Type Identifier in the GFP header does not match the expected value client type (Ethernet or Fibre Channel [FC]). The alarm is valid on the LNW63, LNW66, LNW67, LNW68, and LNW73/73C circuit packs.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Not Alarmed (NA) |
|
AID Type |
VCG |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
MISC (Miscellaneous condition) |
|
Effect on Service |
Standing Condition (SC) |
|
Alarm Entity Type |
VCG |
|
Description |
inc. data type mismatch |
|
Likely Cause |
Inconsistent Equipage: One end of a circuit is equipped with an Ethernet pack and the other end is equipped with a Fiber Channel pack. Incorrect cross-connect provisioning: An Ethernet pack is connected through the network to a Fiber Channel pack. Inconsistent GFP FCS provisioning. |
|
Visible Indication |
None |
|
Action |
Proceed to Procedure 5-48: Clear "inc. data type mismatch" alarm. |