At least 128 consecutive zeros are received in the DS1 signal incoming from the DSX-1, or the energy at the DS1 input is below a preset threshold.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Not Alarmed (NA) |
|
ASAP Type |
DS1 Port |
|
AID Type |
DS1 Port |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
LOS (Loss of Signal) |
|
Effect on Service |
SA or NSA |
|
Alarm Entity Type |
T1 |
|
Description |
inc. (from DSX) DS1 LOS |
|
Likely Cause |
Hard failure of upstream equipment or facility (towards DSX-1). The DS1 input was disconnected at either the backplane or the DSX-1. Equipment is failed or removed at DSX-1. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack. |
|
Action |
Proceed to Procedure 5-50: Clear "inc. (from DSX) DS1" alarms. |