DS1E1 CP failed

Description

An internal equipment failure of the specified 56DS1/E1 circuit pack was detected, or a communications problem between the specified circuit pack and the SYSCTL circuit pack was detected.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

SA Default: Critical (CR)

NSA Default: Minor (MN)

ASAP Type

Circuit pack

AID Type

Slot

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

SA or NSA

Alarm Entity Type

EQPT

Description

DS1E1 CP failed

Likely Cause

An unprotected 56DS1/E1 (LNW8) circuit pack failed - SA.

A protected 56DS1/E1 circuit pack failed - NSA.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the failed circuit pack.

Action

Proceed to Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms.