The bit error ratio (BER) in the DS3 signal incoming from the DSX-3 exceeds the provisioned failure threshold of 10-6 (default).
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Critical (CR) |
ASAP Type |
DS3 Port |
AID Type |
DS3 Port |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
T-BERL (incoming line signal BER thresholds exceeded) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
T3 |
Description |
inc. (from DSX) DS3 sig. failed |
Likely Cause |
Failure of the upstream equipment or facility (towards the DSX-3) Cross talk in office wiring Failure of DS3 circuit pack (12DS3/EC1, 48DS3/EC1, or TMUX). |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-51: Clear "inc. (from DSX) DS3" alarms. |