Two nodes in the BLSR have the same node identifier (NID) or the total number of nodes in the ring is more than 16.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
ASAP Type |
BLSR Protection Group |
AID Type |
BLSR protection group |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
DUPL-RNG (Duplicate Ring Node) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
Duplicate Ring Node |
Likely Cause |
Two nodes on the BLSR have been provisioned with the same node identifier (NID) or a seventeenth ring node has been added to the ring. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-25: Clear "Duplicate Ring Node" alarm. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |