E1 alarm indication signal (AIS) is being received from the near-end E1 termination. Alcatel-Lucent 1665 DMX sends AIS downstream.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Not Alarmed (NA) |
ASAP Type |
E1 Port |
AID Type |
E1 Port |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
AIS (AIS detected) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
E1 |
Description |
inc. (from DSX) E1 AIS |
Likely Cause |
The upstream equipment failed. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-56: Clear "inc. (from DSX) E1" alarms. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |