inc. EC1 line AIS

Description

The system has detected an EC-1 alarm indication signal (AIS) for the specified EC-1 signal.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Critical (CR)

ASAP Type

EC1 Port

AID Type

EC-1 Line

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

AIS (AIS detected)

Effect on Service

SA or NSA

Alarm Entity Type

EC1

Description

inc. EC1 line AIS

Likely Cause

The upstream equipment failed.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack.

Action

Proceed to Procedure 5-57: Clear "inc. EC1" alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.