inc. EC1 RFI-L

Description

The system has detected a line remote failure indicator (RFI-L) returned to a transmitting terminal, indicating that the receiving terminal has detected an incoming signal failure. This alarm was previously called far-end-receive-failure (FERF) and remote defect indication line (RDI-L).

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Alarmed (NA)

ASAP Type

EC1 Port

AID Type

EC-1 Port

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FERF [Line RDI-L (Far End Remote Failure)]

Effect on Service

NSA

Alarm Entity Type

EC1

Description

inc. EC1 RFI-L

Likely Cause

Alarm condition was detected at the far-end EC-1 pack.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-57: Clear "inc. EC1" alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.