The system has detected a line remote failure indicator (RFI-L) returned to a transmitting terminal, indicating that the receiving terminal has detected an incoming signal failure. This alarm was previously called far-end-receive-failure (FERF) and remote defect indication line (RDI-L).
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Not Alarmed (NA) |
ASAP Type |
EC1 Port |
AID Type |
EC-1 Port |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
FERF [Line RDI-L (Far End Remote Failure)] |
Effect on Service |
NSA |
Alarm Entity Type |
EC1 |
Description |
inc. EC1 RFI-L |
Likely Cause |
Alarm condition was detected at the far-end EC-1 pack. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-57: Clear "inc. EC1" alarms. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |