Equipment configuration no longer supported

Description

The system has detected a circuit pack configuration that is not supported by the current software release.

Alarm Data

Value/Meaning

Severity Levels

Minor (MN)

AID Type

Blank

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

DATAFLT (Data Integrity Fault)

Effect on Service

NSA

Alarm Entity Type

COM

Description

Equipment configuration no longer supported

Likely Cause

A function/growth group is equipped with an LNW66/71 circuit pack in one slot and an LNW70/78 circuit pack in the companion slot.

This circuit pack combination is not supported in this release.

Visible Indication

Lighted MN LED on the SYSCTL faceplate

Action

Proceed to Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.