ERP - Multiple RPL Owners

Description

The node provisioned as the RPL Owner received messages that it did not originate that should only come from an RPL Owner.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Major (MJ)

ASAP Type

Fast Ethernet port

Gigabit Ethernet port

VCG port

AID Type

Ethernet 10/100T port

Ethernet GbE port

VCG

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

ERP-MO (ERP - Multiple RPL Owners)

Effect on Service

SA

Alarm Entity Type

FELAN

GELAN

VCG

Description

ERP - Multiple RPL Owners

Likely Cause

More than one node in the ring is provisioned as the RPL owner.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively).

Action

Proceed to Procedure 5-34: Clear "ERP - Multiple RPL Owners" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.