ERP - PDU Watchdog Timeout

Description

A non-RPL owner node hasn’t received R-APS PDUs for 1 minute on both ports (both links are good) or the ring is in the protection state due to a non-local failure (meaning some other node should be sending PDUs), and the RPL-owner node hasn’t received R-APS PDUs for 1 minute on both ports.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Major (MJ)

ASAP Type

Fast Ethernet port

Gigabit Ethernet port

VCG port

AID Type

Ethernet 10/100T port

Ethernet GbE port

VCG

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

ERP-WD (ERP - PDU Watchdog Timeout)

Effect on Service

SA

Alarm Entity Type

FELAN

GELAN

VCG

Description

ERP - PDU Watchdog Timeout

Likely Cause

No RPL Owner is provisioned (or it is shut down), or this node might be using the wrong VLAN or MD level or the R-APS virtual channel may be down.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively).

Action

Proceed to Procedure 5-35: Clear "ERP - PDU Watchdog Timeout" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.