Exceeded MTU size drop

Description

The specified port has detected the Exceeded MTU size drop ratio (Exceeded MTU size drop count/Total frame received count) surpassed the provisioned Exceeded MTU size drop threshold.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Minor (MN)

ASAP Type

Fast Ethernet port

Gigabit Ethernet port

VCG port

AID Type

Ethernet 10/100T port

Ethernet GbE port

VCG

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

EMSD (Exceeded MTU Size Drop)

Effect on Service

NSA

Alarm Entity Type

FELAN

GELAN

VCG

Description

Exceeded MTU size drop

Likely Cause

Local port/VCG provisioning error, or a provisioning error or equipment failure in the network.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively).

Action

Proceed to Procedure 5-36: Clear "Exceeded MTU size drop" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.