The fan shelf failed or the fan filter is clogged.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), or Not Alarmed (NA) Default: Major (MJ) |
|
AID Type |
System Control slot |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
EXT (External failure) |
|
Effect on Service |
CR, MJ, MN = NSA Not Alarmed = Standing Condition (SC) |
|
Alarm Entity Type |
EQPT |
|
Description |
fan shelf failed |
|
Likely Cause |
The fan shelf failed or the fan filter is clogged. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively). None when the severity level is provisioned to NA. |
|
Action |
Proceed to Procedure 5-39: Clear "fan shelf failed" alarm. |