An incoming far end failure indication (FEFI) has been detected on the LAN port. The interfacing customer equipment has detected an incoming failure and is transmitting a far end failure indication (FEFI) downstream.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Not Reported (NR) |
ASAP Type |
Fast Ethernet port |
AID Type |
Ethernet 10/100 Port |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
FERF [Line RDI-L (Far End Remote Failure)] |
Effect on Service |
SA |
Alarm Entity Type |
FELAN |
Description |
inc. FE-LAN FEFI |
Likely Cause |
The interfacing customer equipment has detected an incoming failure and is transmitting a far end failure indication (FEFI) downstream. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-59: Clear "inc. FE-LAN FEFI" alarm. |