inc. FE-LAN FEFI

Description

An incoming far end failure indication (FEFI) has been detected on the LAN port. The interfacing customer equipment has detected an incoming failure and is transmitting a far end failure indication (FEFI) downstream.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Reported (NR)

ASAP Type

Fast Ethernet port

AID Type

Ethernet 10/100 Port

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FERF [Line RDI-L (Far End Remote Failure)]

Effect on Service

SA

Alarm Entity Type

FELAN

Description

inc. FE-LAN FEFI

Likely Cause

The interfacing customer equipment has detected an incoming failure and is transmitting a far end failure indication (FEFI) downstream.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack.

Action

Proceed to Procedure 5-59: Clear "inc. FE-LAN FEFI" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.