inc. FE-LAN LOS

Description

Indicates a loss of signal (LOS) at an input of the local LAN port. This condition indicates that at least 128 consecutive zeros were detected in the Ethernet signal received by the local LAN port.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Critical (CR)

ASAP Type

Fast Ethernet port

AID Type

Ethernet 10/100T Port

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

LOS (Loss of signal)

Effect on Service

SA

Alarm Entity Type

FELAN

Description

inc. FE-LAN LOS

Likely Cause

Disconnected LAN cable or fiber, or failure or removal of interfacing customer LAN equipment.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack.

Action

Proceed to Procedure 5-60: Clear "inc. FE-LAN LOS" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.