GE-LAN CP failed

Description

An internal equipment failure of the specified Gigabit Ethernet circuit pack was detected, or a communication problem between the Gigabit Ethernet circuit pack and the SYSCTL circuit pack was detected.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Critical (CR)

ASAP Type

Circuit pack

AID Type

Slot

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

SA

Alarm Entity Type

EQPT

Description

GE-LAN CP failed

Likely Cause

A Gigabit Ethernet circuit pack failed.

A failure on a Gigabit Ethernet circuit pack is always SA.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the failed circuit pack.

Action

Proceed to Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms.