A circuit pack is present in a slot in a shelf configuration not supported by the software to provide transmission.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) SA Default: Critical (CR) NSA Default: Minor (MN) |
ASAP Type |
Circuit pack |
AID Type |
Slot |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
FACTERM (Facility termination equipment failure) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
EQPT |
Description |
illegal CP type |
Likely Cause |
A slot was occupied and provisioned for a supported circuit pack type. The supported circuit pack was removed, and an unsupported circuit pack type was inserted into that slot: SA. An illegal or unknown circuit pack type has been inserted into the shelf: NSA. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-46: Clear "illegal CP type" alarm. |