Received automatic protection switch (APS) codes are not appropriate for the current bidirectional line-switched ring (BLSR) switch state. Therefore, the switch request on the BLSR does not complete properly.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
|
ASAP Type |
BLSR Protection Group |
|
AID Type |
OC-48 line OC-192 line |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
APSPROV (Improper APS Codes) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
OC48 OC192 |
|
Description |
Improper APS Codes |
|
Likely Cause |
A node in the BLSR is isolated due to |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
|
Action |
Proceed to Procedure 5-47: Clear "Improper APS Codes" alarm. |
| November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |