In bidirectional line-switched rings (BLSRs), there is a rolling window of 12 frames in which 3 consecutive frames must have identical K-bytes. If this requirement is violated, an inconsistent APS codes alarm is generated.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
ASAP Type |
BLSR Protection Group |
AID Type |
OC-48 line OC-192 line |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
APSC (APS codes inconsistent) |
Effect on Service |
NSA |
Alarm Entity Type |
OC48 OC192 |
Description |
Inconsistent APS Codes |
Likely Cause |
A node in the BLSR is isolated due to |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-82: Clear "Inconsistent APS Codes" alarm. |