The "User/Network" parameter values are set the same at both ends of the DCC.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
ASAP Type |
OCn Port |
AID Type |
Section Data Communications Channel (DCC) |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
OSILINKERR (OSI stack error, Data Link Layer) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
inconsistent DCC values |
Likely Cause |
Fibers are misconnected or user network parameter was incorrectly provisioned. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-84: Clear "inconsistent DCC values" alarm. |