The system cannot communicate with the far-end system through the SONET line data communications channel (DCC).
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Minor (MN) |
ASAP Type |
OCn Port |
AID Type |
Data Communications Channel (DCC) |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
EOC-L (line DCC channel failed) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
line DCC channel failed |
Likely Cause |
SYSCTL circuit pack failed, reset, or initialized at the far-end network element. The program installation failed at the far-end network element. The program installation is in progress at the far-end network element. The OC-N OLIU circuit pack failed at the near-end or far-end network element. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-90: Clear "line DCC channel failed" alarm. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |