A user-initiated manual protection switch on line timing references.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Not Alarmed (NA) |
|
AID Type |
OC-3 line OC-12 line OC-48 line OC-192 line |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
WKSWPR-1 (Working facility/equipment switched to protection unit 1) WKSWPR-2 (Working facility/equipment switched to protection unit 2) |
|
Effect on Service |
Standing Condition (SC) |
|
Alarm Entity Type |
OC3 OC12 OC48 OC192 |
|
Description |
manual reference switch |
|
Likely Cause |
User selected Fault → Timing/Sync Protection Switch → System Timing Reference/Source Switch and the Switch Command Manual. The synchronization reference protection switching has been provisioned to revertive. |
|
Visible Indication |
Lighted ABN LED on the SYSCTL faceplate. |
|
Action |
Proceed to Procedure 5-94: Clear "manual reference switch" condition. |