The system has detected multiple valid, but different, generics and cannot select the generic to use.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Minor (MN) |
AID Type |
Blank |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
DATAFLT (Data Integrity Fault) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
Multiple Generics |
Likely Cause |
A new nonvolatile memory (NVM) module was installed with a valid generic different from the old generic, and the system cannot select the generic to use. |
Visible Indication |
Lighted MN LED on the SYSCTL faceplate |
Action |
Proceed to Procedure 5-44: Clear "Generic/Database/Equipment Configuration" alarms/conditions. |