An internal equipment failure of the specified Muxponder circuit pack, or a communications problem between the specified circuit pack and the SYSCTL circuit pack was detected.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Critical (CR) |
ASAP Type |
Circuit pack |
AID Type |
Slot |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
FACTERM (Facility termination equipment failure) |
Effect on Service |
SA |
Alarm Entity Type |
EQPT |
Description |
Muxponder CP failed |
Likely Cause |
A Muxponder circuit pack failed. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the failed circuit pack. |
Action |
Proceed to Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |