Transmission audits are enabled on the circuit pack and the system has detected a network processor audit failure.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) SA Default: Critical (CR) NSA Default: Minor (MN) |
ASAP Type |
Circuit pack |
AID Type |
Slot |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
NPAUDT (NP audit failed) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
EQPT |
Description |
NP audit failed |
Likely Cause |
A failed device on the circuit pack caused a packet flow problem, or there are excessive broadcast type Ethernet frames running through the network processor. The maximum through capacity is 9 Gigabits. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-4: Clear "audit failed" alarms. |